BIO ABSORBABLE PIN AVAIBLE SIZES

Pin Diameter: 1.5 mm & Pin Length: 50 mm

Pin Diameter: 2 mm & Pin Length: 50 mm

Manufacturing in compliance with 93/42/EC directive,
Pins have rounded tips and are cutable to meet specific needs,
These pins were designed to specifically aid in the long term mending of minor fractures in the epiphyseal area of the bone, for surgeries on the lower and upper extremities of the body.
The pins are avaible in two size; 1,5 mm and 2 mm.

Products are indicated for maintenance of alignment and fixation of bone fractures, osteotomies, arthrodeses or bone grafts in the presence of appropriate additional immobilization.

Bio-absorbable, the screws are made from a biocompatible amorphous copolymer,
Excellent biocompatibility of PLDLA and its breakdown products (CO2 and H2O).

It stabilizes 8-10 months after surgery and provides good healing and simplifies future revisions. It is then slowly hydrolyzed with water from the tissues and after 24 months, completely healthy bone forms.

Femoral: Poly (%70 L/% 30 DL-lactide)

BIO ABSORBABLE JAGGED PIN SIZES

Pin Diameter: 1.5 mm & Pin Length: 40 mm

Pin Diameter: 2.7 mm & Pin Length: 50 mm

Manufacturing in compliance with 93/42/EC directive,
Pins have rounded tips and are cutable to meet specific needs,
Jagged design of these pins provides a maximum grip on the bone,
The pins are avaible in two size; 2 mm and 2,7 mm.

2 mm Bio Jagged Pin indications are listed below:
Apical fragements: e. g. fractures of the radial head, fracture of the patella rim, fractures at the proximal and distal ends of the metatarsal and metacarpal bones.
Osteochondral fractures or dissections: e.g. ankle-bone dome, femoral condyle, cancellous fragments or those subject to low stresses: e.g. layered reconstruction of fractures of the heel or acetabulum, corticocancellous grafting of chips.

2,7 mm Bio Jagged Pin indications are listed below:
Large osteochondral fragments: e.g. fractures of the femur head (Pipkin fractures), fractures of the malleolus (Weber A fractures), fractures of the radius, longitudinal fractures of the patella.

Bio-absorbable, the screws are made from a biocompatible amorphous copolymer,
Excellent biocompatibility of PLDLA and its breakdown products (CO2 and H2O).

It stabilizes 8-10 months after surgery and provides good healing and simplifies future revisions. It is then slowly hydrolyzed with water from the tissues and after 24 months, completely healthy bone forms.

Femoral: Poly (%70 L/% 30 DL-lactide)